Recall: Lasko Recalls Box Fans Due To Fire Hazard


FOR IMMEDIATE RELEASE
March 24, 2011
Release #11-183
Firm's Recall Hotline: (877) 445-1314
CPSC Recall Hotline: (800) 638-2772
CPSC Media Contact: (301) 504-7908

Lasko Recalls Box Fans Due To Fire Hazard

WASHINGTON, D.C. - The U.S. Consumer Product Safety Commission, in cooperation with the firm named below, today announced a voluntary recall of the following consumer product. Consumers should stop using recalled products immediately unless otherwise instructed. It is illegal to resell or attempt to resell a recalled consumer product.

Name of Product: Box fans

Units: About 4.8 million units

Manufacturer: Lasko Products Inc., of West Chester, Pa.

Hazard: An electrical failure in the fan's motor poses a fire hazard to consumers.

Incidents/Injuries: Lasko has received seven reports of fires associated with motor failures, including two house fires and one barn fire, resulting in extensive property damage. No injuries have been reported.

Description: This recall involves Lasko box fans with model numbers 3720, 3723, and 3733 and Galaxy box fans with model number 4733 that have date "2002-03" or "2003-04" stamped on the bottom of the metal frame. "Lasko" or "Galaxy" is printed on the front of the fan. The model number is either stamped or printed on the bottom of the fans.

Sold at: Mass merchandisers nationwide from July 2002 through December 2005 for between $12 and $25.

Manufactured in: United States

Remedy: Consumers should immediately stop using the recalled fans and contact Lasko to receive a free fused plug safety adapter.

Consumer Contact: For additional information, contact Lasko toll free at (877) 445-1314 anytime or visit the firm's website at www.laskoproducts.com


Picture of recalled model 3720 Lasko box fan

Model Number 3720



Picture of recalled model 3723 Lasko box fan

Model Number 3723



Picture of recalled model 3733 Lasko box fan

Model Number 3733



Picture of recalled model 4733 Galaxy box fan

Model Number 4733