Recalls: Electrical Systems

January 20, 2011 Poulan Pro Generators Recalled by Husqvarna Professional Products Due to Fire Hazard

This recall involves gas-powered Poulan Pro Generators designed for residential use. Models included in the recall are: PP4300, PP6600, PP6600E and PP7600E, all serial numbers. The generator's model number can be found on the front of the fuel tank on the Serial Number Plate. The generators are black and marigold color, measure 21.5" H x 26.6" L x 21.3" range from 4.4 to 7.6 KW with two handles and two wheels. Read more.


January 18, 2011 Schneider Electric Recalls Xantrex GT Series Grid Tie Solar Inverters Due to Injury Hazard

The recalled inverter converts solar photovoltaic voltages into utility grid voltages; allowing the owner to feed power into the electrical grid. The recalled units were manufactured between September 2005 and August 2010. These products were sold under the Xantrex, Sunpower, and General Electric brands. The brand name is printed on the front of the unit. Read more.


September 23, 2010 Siemens Recalls Circuit Breakers Due to Fire Hazard

This recall involves Siemens and Murray 15 through 50 AMP single and double pole circuit breakers, load centers (circuit breakers that come with an electrical panel), and meter combos (contain a load center and a meter socket). “Siemens” or “Murray,” date codes 0610 or 0710 and the catalog number are printed on a label on the side of the circuit breakers. Date codes between June 2010 through August 2010 are stamped on the inside of the metal box of the load centers and meter combos. The catalog number for the load centers and meter combos is printed on a label inside the metal box door and on the packaging. Read more.


August 18, 2010 Electrical Wire Recalled by Cerro Wire due to Fire Hazard

This recall involves THNN electrical wire labeled on its packaging as 12 gauge solid white 100’ UPC 48243982721 and 12 gauge stranded red 50’ UPC 48243229215. The actual wire has “THHN Cerro Wire 14 gauge” printed on it. The UPC number and 12 gauge is found on the plastic wrap and on a label at the bottom of the reel. Read more.


August 2, 2010 Miami Breaker Recalls Counterfeit Square D Circuit Breakers Due to Fire Hazard

The counterfeit circuit breakers are marked as Square D in the QO series. The models are QO115 (about 7,800 units), QO120 (about 26,300 units), QO130 (about 3,200 units), QO215 (about 350 units), QO220 (about 720 units), QO230 (about 1,780 units), QO240 (about 1,130 units), QO250 (about 1,150 units) and QO260 (about 1,150 units). Genuine Square D QO breakers have the following: (1) the amp rating written on the handle in white paint on the front of the breaker, (2) the Square D insignia molded onto the breaker side; (3) a yellow chromate clip with half of the top of the clip visible. If your breaker does not match this description, it could be counterfeit. Read more.


May 25, 2010 Cummins Power Generation Recalls Portable Generators Due to Fire Hazard

This recall involves Cummins Onan Portable Generators. "Cummins Onan" and the model number are printed on the front of the generator. The serial number is printed on the generator's name plate. Only generators manufactured on or after June 2009 and before December 2009 are included in this recall. Read more.


February 18, 2010 Motor Controllers for Submersible Pump Systems Recalled by Franklin Electric Due to Shock Hazard

This recall involves the Pumptec electronic motor controller for 115v/230v submersible motors rated 1/3 to 1 1/2 HP with model number 5800020600 and date codes of 06F45 through 09L45. The model number and date code can be found on the nameplate label located on the right-hand side of the enclosure. Read more.


October 15, 2009 Single Meter Sockets Recalled by Milbank Manufacturing Due to Fire and Electrocution Hazards

The single meter 200 amp/4 terminal sockets are used for underground utility meter installations. The meter socket is 20 3/4 inches high by 9 inches wide and 4 1/2 inches deep with 1 meter position. It is used by the approving utility to mount their electric meter to measure how much electricity a residence uses. It can be used for an underground residential application. The recalled model number 9090 appears on the right or left side of the installed meter socket. If not installed, model numbers U9090-O or R9090-O will appear on the label on the outside of the box. Read more.


August 13, 2009 Homelite, Husky and Black Max Generators Recalled Due to Fire Hazard; Sold Exclusively at Home Depot and Sam's Club Stores

This recall involves Homelite and Husky brand generators sold exclusively at Home Depot stores and Black Max brand generators sold exclusively at Sam’s Club stores. Affected generators include Homelite models HG3500, HG3510, HG5700 and HG5700R, Husky models HU3650, HUCA5700 and HUCA7000 and Black Max models BM10700, BM10700A, BM10700B, BM10711A, BM10700DG, BM10700R, BM10700BR & BM10722G. Generators included in this recall have manufacturing date codes between BML306-BMM151, CHL122-CHM151 and CRL153-CRM059. The model number and manufacturing date code are included on the data label located on the top or side of the generator engine. Products with a green “dot” on the outside of the package or a “silver dot” on the fuel gauge face are not included in the recall. Read more.


July 1, 2009 Intermatic Recalls In-Wall Timers Due to Shock Hazard

This recall involves the Intermatic in-wall electronic timers with model numbers ST01, ST01C, ST01AC, ST01AC70, ST01C70, ST01CL, EI600C, EI600LAC, EI600LAC8, EI600WC, and EI600WC8. This product is a lamp and appliance timer and typically takes the place of a standard wall switch. The timer is white, off-white, or almond and measures 2 1/2 inches high by 1 3/4 inches wide. Model numbers can be found on the packaging and on the instruction. In-Wall timers are included in this recall if (1) the brand name “Intermatic” is molded on the front of the timer cover door, (2) the timer has only four keypad buttons, and (3) there is no 3-digit date code (e.g. “04C”) stamped on the inside of the timer cover door. Timers with a 3-digit date code (e.g. “04C”) stamped on the inside of the timer cover door are not included in this recall. Read more.