Recalls: Boilers

December 20, 2019 Bosch Thermotechnology Recalls Buderus Boilers Due to Carbon Monoxide Poisoning Hazard

This recall involves Buderus brand GB125-35 oil-condensing boilers distributed by Bosch. The boilers have a blue enclosure, and the GB125-35 model number is located on the data plate near the top right hand side of the boiler. The Buderus brand name is printed on the outside of the boiler's blue enclosure. Bosch Thermotechnology and the model number are printed on a white label on the blue enclosure. Read more.


April 25, 2019 Viessmann Recalls Boilers Due to Carbon Monoxide Hazard

This recall involves the Vitodens 200-W and Vitodens 222-F series boilers used for space or domestic water heating. There are five affected models in a specific serial number range. The Vitodens 200-W is a wall hung unit, housed in a white metal box about 38 inches high and 18 inches wide. The Vitodens 222-F is a floor mounted unit, housed in a white metal box about 68 inches tall and 24 inches wide. The name "Vitodens" is printed on the label on the outside of the boiler box. The product name and model number can be found on the left side of the boiler cover. The serial number can be found on the underside of the wall mounted boiler and on the center section on the floor mount model. Product Model Part Number Serial Number Range Vitodens 200-W B2HB 19 7538092 7538092401003107 to 7538092701038106 B2HB 26 7538093 7538093401002107 to 7538093701177109 B2HB 35 7538094 7538094401003101 to 7538094701446103 Vitodens 222-F B2TB 19 7542250 7542250401001100 to 7542250401210106 B2TB 35 7542251 7542251401001107 to 7542251701257105 Read more.


October 18, 2018 Hydrolevel Recalls Controllers for Slant/Fin Boilers Due to Fire Hazard

This recall involves the Hydrolevel HydroStat Model 3000 boiler controller which is a black rectangular control unit for residential Slant/Fin VSPH boilers. The unit has six small LED lights and the word 'Hydrostat' on the front. The controller says HydroStat on the front and HydroStat Model 3000 on the back. Read more.


May 15, 2018 NY Thermal Recalls Boilers Due to Carbon Monoxide Hazard

This recall involves NY Thermal (NTI) manufactured gas boilers sold under the Trinity Tft and Slant/Fin CHS brand names used for residential and commercial use. The Trinity Tft models have the name "NTI" printed on the front and were sold in metallic-grey. The Trinity Tft60 through Tft250 model boilers measure 33 inches tall by 20 inches wide. The Trinity Tft300 through Tft399 model boilers measure 36 inches tall and 25 inches wide. The Slant/Fin CHS models have the name "Slant/Fin" and "CHS" printed across the front bottom and were sold in white. The Slant/Fin CHS-85 through CHS-250 model boilers measure 33 inches tall by 20 inches wide. The Slant/Fin CHS-300 through CHS-399 model boilers measure 36 inches tall and 25 inches wide. The model and UPC numbers are printed on the nameplate located on the right side of the boiler. The following model and UPC numbers are included in this recall: Brand Name Model UPC Trinity Tft Tft60 628233731005 Trinity Tft Tft85 628233731036 Trinity Tft Tft110 628233731067 Trinity Tft Tft155 628233731098 Trinity Tft Tft175 628233731128 Trinity Tft Tft200 628233731159 Trinity Tft Tft250 628233731180 Trinity Tft Tft300 628233731210 Trinity Tft Tft340 628233733467 Trinity Tft Tft399 628233731241 Slant/Fin CHS CHS-85 42541025395 Slant/Fin CHS CHS-110 42541025401 Slant/Fin CHS CHS-155 Not available Slant/Fin CHS CHS-175 42541025463 Slant/Fin CHS CHS-200 42541025470 Slant/Fin CHS CHS-250 42541025487 Slant/Fin CHS CHS-300 Not available Slant/Fin CHS CHS-340 Not available Slant/Fin CHS CHS-399 42541025500 Read more.


March 10, 2016 Carlin Recalls Williamson and Thermoflo Furnaces and Boilers Equipped with Carlin Burners Due to Fire Hazard (Recall Alert)

The recall includes Williamson and Thermoflo furnaces and boilers with Carlin oil burners with an installation date label between April 1, 2015 and November 31, 2015. The installation date is printed on a label on the outside of the furnace or boiler. Recalled furnaces have a Carlin burner inside of the furnace, behind the furnace grate. Recalled boilers have a Carlin burner attached to the outside of the boiler enclosure. "Carlin" is printed in white letters on the face of the burner nameplate. Read more.


February 25, 2016 Viessmann Recalls Gas Boilers Due to Fire and Carbon Monoxide Hazard (Recall Alert)

This recall involves the Vitodens 200-W condensing gas boilers used for residential use. These wall-hung units are housed in a white metal box that measures about 43.5 inches tall by 19 inches wide by 21 inches deep. There are two models: B2HB-45 and B2HB-57 included in this recall. The name "Vitodens" and "Viessmann" are printed on the label on the outside of the boiler box. The product name and model number can be found on the boiler rating plate located on the left side of the white boiler cover. The serial number can be found on a separate label under the boiler cover or on the left hand side of the unit. Recalled boilers do not have a blue dot with a handwritten data label on it. The two models of boilers included in the recall have the following serial number ranges: Product Name Model Numbers Serial Number Range Vitodens 200-W B2HB-45 7554703501001105 to 7554703501369106 B2HB-57 7554704501001102 to 7554703501411109 Read more.


October 9, 2014 Fluid Handling Recalls Low Water Cut-Off Control Units for Hot Water or Steam Boilers Due to Fire and Explosion Hazards (Recall Alert)

This recall involves McDonnell and Miller series 750 Low Water Cut-Off control units, which in connection with a water level sensor, are used as a primary or secondary safety control on hot water or steam boilers to signal the boiler to provide protection in low water conditions. The unit is mounted on the outside of a boiler, generally near the boiler's main electrical panel. They are black and measure about 6 inches high x 5 inches wide x 2 1/2 inches deep. The units have a green LED "On" light, a red LED "Low Water" light and test and manual reset buttons on the top. "McDonnell and Miller," "Guard Dog," "Low Water Cut-Off" and model numbers 750-MT-120, 751-MT-120, 751P-MT-120 or 752P-MT-24 are printed on a white label on the outside of the unit. Date codes G41 or H41 are inked on the inside back plate. Read more.


June 10, 2014 Weil-McLain Recalls Ultra Series Boilers Due to Risk of Fire, Explosion

This recall involves Weil-McLain Ultra models 80, 105, 155 and 230 MBH gas-fired boilers used for space heating. The boilers have a serial number range between CP 6557046 and CP 6955985. Model and serial numbers are located on a bar-coded label affixed to the lower right side of the boiler, behind the removable front panel. The boilers have a Weil-McLain logo plate affixed to the front, a pewter/flat black cover and are either freestanding or wall-mounted. Read more.


January 9, 2014 New Yorker Boiler Recalls Home Heating Boilers Due to Carbon Monoxide Hazard

This recall involves New Yorker Boiler PVCGA model cast iron hot water boilers that use natural gas or liquid petroleum to heat water for residential space heating. The boilers are green in color, about 38 inches tall and about 26 inches deep and range from 11 to 30 inches wide. The front cover of the boiler is vented and has the New Yorker Boiler logo. Recalled boilers were manufactured between May 2012 and February 2013. The model number, serial number and manufacturing date are located on a silver label on the inside panel. The manufacturing date appears in the upper right corner of the silver label in the MM/YYYY format. The following model numbers and serial number ranges are included in this recall: Model Number PVCG50ANI PVCG60ANI PVCG70ANI PVCG80ANI PVCG90ANI PVCG30API PVCG40API PVCG50API Serial Number Range 65320695 through 65383954 Read more.


January 9, 2014 U.S. Boiler Recalls Home Heating Boilers Due to Carbon Monoxide Hazard

This recall involves U.S. Boiler ESC, PVG and SCG model cast iron hot water boilers that use natural gas or liquid petroleum to heat water for residential space heating. The boilers are light blue in color with black trim, about 40 inches tall, about 26 inches deep and range from 12 to 31 inches wide. The model name and U.S. Boiler logo are on the front cover of the boiler. The front cover of the boiler is vented. Recalled boilers were manufactured between December 2005 and February 2013. The model number, serial number and manufacturing date are located on a silver label on the top panel of ESC models and on the inside of PVG and SCG models on the right side panel. The manufacturing date appears in the upper right corner of the silver label in the MM/YYYY format. The following model numbers and serial number ranges are included in this recall: Model Number Serial Number Range ESC3 through ESC9 65249110 through 65382278 PVG3_P, PVG4_P and PVG5 through PVG9 64870666 through 65385748; 97939433 SCG3 through SCG9 35200197; 65283322 through 65858729 Read more.